Heatless adsorption dryers with pre- and after- filters
Flow Capacity: 80 - 5000 cfm
MICROPROCESSOR CONTROL
The microprocessor control enables energy
efficient control of the adsorption dryer.
Optional dew point control reduces the
regeneration air volume depending on
temperature, pressure and output quantity.
FUNCTION DISPLAY
A functional display at the front of the control cabinet permanently indicates operational status. The ten-minute cycle can save up to six percent of energy. The compressor synchronizing control can also offer further energy savings potential.
FILTRATION
The entire range is equipped with both pre and after filter as standard. Even before drying, all solids and aerosols up to 0.01 ppm are removed from the compressed air supply – assuring best possible quality.
LOW RESIDUAL OIL CONTENT
The BHLD series can be equipped with an activated carbon adsorber to ensure a residual oil content of only 0.003 ppm – for the highest quality compressed air
The all-in one package for dry compressed air:
The ideal solution for compressed air pressure dew points below 38°F. The heatless BOGE adsorption dryers can reach dew points of -70°F (standard -40°F). The twin tower system allows regeneration simultaneously with the adsorption eliminating the need for any external power supply.
BOGE Model |
Capacity | Dimensions H x W x D | Compressed Air Connection | Voltage standard | Weight | |
---|---|---|---|---|---|---|
m³/h | cfm | in. | lbs. | |||
BHLD - 80 | 136 | 80 | 77 x 30 x 24 | 3/4" FLG | 110V/60HZ | 384 |
BHLD - 100 | 170 | 100 | 77 x 30 x 24 | 1" FLG | 110V/60HZ | 550 |
BHLD - 150 | 255 | 150 | 85 x 34 x 24 | 1" FLG | 110V/60HZ | 600 |
BHLD - 200 | 340 | 200 | 86 x 34 x 24 | 1½" FLG | 110V/60HZ | 850 |
BHLD - 250 | 425 | 250 | 87 x 46 x 30 | 1½" FLG | 110V/60HZ | 975 |
BHLD - 300 | 510 | 300 | 87 x 46 x 30 | 1½" FLG | 110V/60HZ | 1050 |
BHLD - 350 | 595 | 350 | 89 x 46 x 30 | 2" FLG | 110V/60HZ | 1100 |
BHLD - 450 | 765 | 450 | 91 x 50 x 30 | 2" FLG | 110V/60HZ | 1200 |
BHLD - 500 | 850 | 500 | 91 x 50 x 30 | 2" FLG | 110V/60HZ | 1250 |
BHLD - 600 | 1019 | 600 | 91 x 50 x 30 | 2" FLG | 110V/60HZ | 2000 |
BHLD - 750 | 1274 | 750 | 93 x 66 x 40 | 3" FLG | 110V/60HZ | 2700 |
BHLD - 1000 | 1699 | 1000 | 98 x 70 x 40 | 3" FLG | 110V/60HZ | 3900 |
BHLD - 1250 | 2124 | 1250 | 98 x 70 x 40 | 3" FLG | 110V/60HZ | 4090 |
BHLD - 1500 | 2549 | 1500 | 109 x 93 x 50 | 4" FLG | 110V/60HZ | 5500 |
BHLD - 2000 | 3398 | 2000 | 109 x 93 x 50 | 4" FLG | 110V/60HZ | 6000 |
BHLD - 2500 | 4248 | 2500 | 115 x 112 x 60 | 4" FLG | 110V/60HZ | 6800 |
BHLD - 3000 | 5097 | 3000 | 120 x 120 x 70 | 6" FLG | 110V/60HZ | 9000 |
BHLD - 3500 | 5947 | 3500 | 125 x 120 x 70 | 6" FLG | 110V/60HZ | 9600 |
BHLD - 4000 | 6796 | 4000 | 128 x 120 x 75 | 6" FLG | 110V/60HZ | 10500 |
BHLD - 4500 | 7646 | 4500 | 130 x 130 x 80 | 6" FLG | 110V/60HZ | 11000 |
BHLD - 5000 | 8495 | 5000 | 135 x 130 x 80 | 6" FLG | 110V/60HZ | 12300 |
Example Compressed air to be dried to -40° | |
---|---|
Given Flow | 350 scfm |
Min. operating pressure | 120 psig |
Max. inlet temperature | 100 ˚F |
Pressure dew point | -40 ˚F |
Capacity correction factors for system air pressure (C1) | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
System Pressure(psig) | 60 | 70 | 80 | 90 | 100 | 110 | 120 | 130 | 140 | 150 |
Correction Factor | 0.65 | 0.73 | 0.82 | 0.91 | 1 | 1.09 | 1.18 | 1.27 | 1.35 | 1.44 |
Capacity correction factors for inlet air temperature (C2) | ||||||||
---|---|---|---|---|---|---|---|---|
Inlet Temperature (˚F) | 70 | 80 | 90 | 100 | 105 | 110 | 115 | 120 |
Correction Factor | 1.2 | 1.15 | 1.1 | 1 | 0.9 | 0.8 | 0.7 | 0.6 |
*For inlet temperatures above 100°F, molecular sieve desiccant is required.
Content © Copyright | Manufacturers Distributor, Inc. - mdi Sales
Site Use Acknowledges Acceptance of our Privacy Statement and our Terms of Service
Reveal makes these very easy to summon and dismiss. The close button is simple an anchor with a unicode
character icon and a class of close-reveal-modal
. Clicking anywhere outside the modal will
also dismiss it.